Stranded aluminum core Sta/Swa armored open air, conduit, pipe XLPE insulated PVC sheathed power cable

Product DescriptionMedium Voltage Cable1. ApplicationThe product is suitable for use in power transmission and distribution lines with rated power frequency voltage 3.6/6kv~26/35kv.2. Structure:1. Conductor shape: Aluminum Or Copper2. Conductor screen: Semi-conductive material3. Insulation: XLPE4. Insulation screen: Semi-conduct

Featured Products

Product Description

Medium Voltage Cable

1. Application

The product is suitable for use in power transmission and distribution lines with rated power frequency voltage 3.6/6kv~26/35kv.

2. Structure:

Stranded Aluminum Conductor Armoured XLPE Insulated PVC Sheathed Power Cable

1. Conductor shape: Aluminum Or Copper
2. Conductor screen: Semi-conductive material
3. Insulation: XLPE
4. Insulation screen: Semi-conductive material
5. Armoured: Steel wire armour or steel tape armour or alumium wire armour
6 Sheath: PVC or MDPE, HDPE, LDPE

3. Operating characteristics

- Rated power-frepuency voltage U0/U: 3.6/6kv~26/35kv.
- Max.admissible operating temperature of the conductor:90ºC.
- Max. short-circurt temperature of conductor shall not exceed 2500C. (5s maximum duration)
- The ambient temperature under installation should not below 0ºC.
- The bending radius of a single-core cable should not less than 20 times of the cable diameter.
  The bending radius of a multi-core cable should not less than 15 times of the cable diameter. 

4. Table of the voltage, cores and cross-section
8.7/10kV,8.7/15kV  Single Core  Basic Parameters
Nominal Cross Section
(mm)
Thickness of Insulation mmThickness of Copper Tape mmYJV,YJLVApprox. weight of cable(kg/km)YJV62,YJLV62Approx. weight of cable(kg/km)
Thickness of Sheath mmOverall Diameter of Cable mmYJVYJLVThickness of
PVC Insulation mm
Thickness of Non-magnetic Steel tape mmThickness of Sheath mmOverall Diameter of Cable mmYJV62YJLV62
254.50.121.822.86723 574 1.20.21.826.061020 871 
354.50.121.823.86839 632 1.20.21.827.061149 942 
504.50.121.824.56967 688 1.20.21.927.961299 1019 
704.50.121.826.061196 792 1.20.21.929.461547 1143 
954.50.121.827.761478 917 1.20.2231.361866 1305 
1204.50.121.929.261745 1038 1.20.2232.662138 1431 
1504.50.121.930.562027 1154 1.20.22.134.162452 1580 
1854.50.12232.462414 1323 1.20.52.237.263208 2117 
2404.50.122.134.863018 1564 1.20.52.239.463848 2395 
3004.50.122.136.763590 1790 1.30.52.341.764507 2707 
4004.50.122.339.764438 2136 1.30.52.444.565402 3101 
5004.50.122.343.565608 2608 1.40.52.548.766712 3712 
6304.50.122.547.067020 3147 1.40.52.652.068182 4308 
 
8.7/10kV,8.7/15kV  3 cores  Basic Parameters
Nominal Cross Section
(mm)
Thickness of Insulation mmThickness of Copper Tape mmYJV,YJLVApprox. weight of cable(kg/km)YJV22,YJLV22Approx. weight of cable(kg/km)
Thickness of Sheath mmOverall Diameter of Cable mmYJVYJLVThickness of PVC Insulation mmThickness of Galvanized Steel tape mmThickness of Sheath mmOverall Diameter of Cable mmYJV22YJLV22
254.50.12.445.6 2365 1916 1.40.52.550.6 3495 3046 
354.50.12.547.9 2733 2111 1.40.52.652.9 3918 3295 
504.50.12.649.6 3210 2367 1.50.52.754.8 4463 3620 
704.50.12.753.1 3936 2719 1.50.52.858.3 5272 4055 
954.50.12.857.0 4854 3165 1.60.5362.6 6346 4657 
1204.50.12.960.0 5677 3547 1.70.53.165.8 7278 5148 
1504.50.1363.0 6613 3986 1.70.53.268.8 8291 5664 
1854.50.13.166.8 7785 4498 1.80.53.372.8 9600 6313 
2404.50.13.372.0 9749 5371 1.90.53.578.2 11737 7360 
3004.50.13.576.5 11580 6160 20.83.784.1 14533 9113 
4004.50.13.782.5 14229 7297 2.10.83.990.3 17451 10519 
5004.50.13.991.1 18058 9020 2.20.84.199.1 21656 12618 
6304.50.14.198.2 22403 10737 2.40.84.4106.8 26431 14765 

5. Type and Name
 
TypeDesignationApplications
YJVCopper conductor,XLPE insulated,PVC sheathed power cableFor laying indoors,in tunnel or cable trench,unable to bear external mechanical forces.Single core cable is not allowed to laid in magnetic duct.
YJLVAluminum conductor,XLPE insulated,PVC sheathed power cable
YJYCopper conductor, XLPE insulated,PE sheathed power cable
YJLYAluminum conductor, XLPE insulated,PE sheathed power cable
YJV22Copper conductor,XLPE insulated,steel tape armoured,PVC sheathed power cableFor laying indoors,in tunnel in cable trench,or direct in ground,able to bear external mechanical forces.Single core cable is not allowed to laid in magnetic duct.
YJLV22Aluminum conductor,XLPE insulated,steel tape armoured,PVC sheathed power cable
YJV23Copper conductor,XLPE insulated,steel tape armoured,PE sheathed power cable
YJLV23Aluminum conductor,XLPE insulated,steel tape armoured,PE sheathed power cable
YJV32Copper conductor,XLPE insulated,steel wire armoured,PVC sheathed power cableFor laying indoors,in tunnel cable trench,well or direct in ground,able to bear external mechanical forces and certain pulling force.
YJLV32Aluminum conductor,XLPE insulated,steel wire armoured,PVC sheathed power cable
YJV33Copper conductor,XLPE insulated,steel wire armoured,PE sheathed power cable
YJLV33Aluminum conductor,XLPE insulated,steel wire armoured,PE sheathed power cable
6. Our Factory

Stranded Aluminum Conductor Armoured XLPE Insulated PVC Sheathed Power Cable
Stranded Aluminum Conductor Armoured XLPE Insulated PVC Sheathed Power Cable
Stranded Aluminum Conductor Armoured XLPE Insulated PVC Sheathed Power Cable
Stranded Aluminum Conductor Armoured XLPE Insulated PVC Sheathed Power Cable

7. Our Honor

Stranded Aluminum Conductor Armoured XLPE Insulated PVC Sheathed Power Cable
Stranded Aluminum Conductor Armoured XLPE Insulated PVC Sheathed Power Cable


8. Contact Details

DAN ZHAO | Taifeng Cable Co., Ltd.
Add.: Heda Center, No.177 Tailiu Road, Shibei District, Qingdao, China
Factory Add.: No.1 Taifeng Road, Dacaozhuang Administrative Zone, Xingtai City, Hebei Province, China
  
Phone: 0086 17863817629
Website: taifengcable.en.made-in-china.com
  

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours